Varilight V-Pro IR Instructions

V-Pro IR dimmers are set to run in trailing-edge Mode 1 by default.

This versatile mode is suitable for most dimmable LEDs. It is also

gentler on the load. Some types of dimmable LED perform best with

leading-edge control. This dimmer can easily be set to run in leading

edge Mode 2 by following the instructions under "Programming". Mode

3 is suitable for some external LED drivers.

The V-Pro IR master dimmer is suitable for 1-way circuits. For 2-way

(or multi-way) circuits, use a V-Pro IR master dimmer with one or more

dimming slave units. V-Pro IR touch/remote dimmers cannot be used

in conjunction with conventional switches in a 2-way circuit. Use only

on an electricity supply of 216-253V~.

Dimming slaves are touch control only. Remote control is only possible

for the master unit.

This product complies with European Safety Regulations (IEC 669-2-

1 or BSEN60669-2-1) when used in lighting circuits containing MCBs

(miniature circuit breakers). These can be rated at 6A, 10A or 16A

(preferably 6A for lighting circuits). Your guarantee is not affected if

you have an older lighting circuit protected by fuse wire links.

www.varilight.co.uk for latest loading advice);

Always observe the recommended maximum load.

Dimmable Mains

1 to 10 Dimmable LEDs (max. 100W)

Check your LED lamps are suitable for use with

dimmers that have a standby mode. A load

regulator may be required, e.g. Varilight Glowfix

Low Voltage LED

[USE DEFAULT

MODE 1 ONLY]

Incandescent

Mains Halogen

Low Voltage

Maximum of 10 lamps for GLS and Halogen loads

Dimmable CFL

Use MODE 3: Digiflux Mode [see "Programming"]

Visit www.varilight.co.uk/digiflux for latest advice

THIS SWITCH IS SUITABLE FOR

Most dimmable LEDs

Mains voltage incandescent GLS or candle-shaped bulbs;

GU10 or similar mains halogen bulbs

Dimmable electronic low voltage transformers

Dimmable CFLs (Use Mode 3)

THIS SWITCH IS NOT SUITABLE FOR:

Non-dimmable fluorescent bulbs and tubes;

Wire-wound or toroidal transformers;

Electric motors

OVERLOAD PROTECTION:

This dimmerswitch is protected against overload. If an overload occurs

it will automatically turn off until the overload is removed and the

dimmerswitch is switched off and then switched back on again.

However, if the dimmerswitch receives a total short-circuit it may be

damaged beyond repair.

dimmerswitches

For 1 to 8 Digiflux CFLs

www.varilight.co.uk

Please record the batch number printed on the side

of the plastic moulding on the rear of the product. This

will assist us in providing any technical support you

may require.

INSTALLERS – Please leave these instructions with your customer

for future reference.

LOADING (Continued)

TRANSFORMERS

Use only with quality dimmable electronic transformers. For optimum

performance choose VARILIGHT transformers*.

To calculate load, add the VA ratings of the transformers (not the

wattage of the bulbs). Choose transformers with a maximum rating

close to their lamp load (eg. Use a 50VA, 60VA or 70VA transformer

to control a 50W low voltage bulb).N.B. Certain transformers may not

behave according to their power rating when used with a

dimmer. An overload will result in the dimmer turning itself off. If this

happens, change your transformer(s) (VARILIGHT transformer(s)

recommended); or remove one (or some) transformer(s) from the

circuit; or choose a higher rated dimmer instead.

* If a transformer appears as a highly inductive load, e.g. Wire-wound

or toroidal transformers, the dimmer will not work. To protect itself it

will turn off within 1 second.

ADVICE ON CHANGING LIGHT BULBS

Always turn off the mains power when light bulbs controlled by your V-

Pro IR dimmers are replaced. If you change the type of light bulb then

restore factory settings as described under "Programming".

FREQUENTLY ASKED QUESTIONS

For FAQs, please visit: www.varilight.co.uk/faqs

In case of any defect, return the dimmer to our service department.

Varilight undertakes to repair or replace, at its discretion, goods which

have become defective within 12 months of purchase, solely as a

result of faulty materials and workmanship, provided that:-

a) The unit has been correctly fitted according to the instructions and

has not been used with an incompatible load, fluorescent tubes, or

overloaded beyond its rating, and has only been used on a 200-250V

a.c. power supply.

b) The dimmer module has not been tampered with or taken apart.

c) The unit is securely packed and safely returned to Service

Department, Carylls Lea, Faygate, Horsham, West Sussex, RH12 4SJ

(Tel. (01293) 851584) together with a letter stating the guarantee

registration number below, the date and place of purchase, the type

and wattage of the lighting or other load being controlled and the

details of the fault. This guarantee states Varilight's entire liability,

which does not extend to cover consequential loss or damage or

installation costs arising from a defective product. The guarantee does

not apply to problems arising from any incompatibility between your

lamps and the dimmer switch. This guarantee does not in any way

affect the statutory rights of the purchaser and is offered so that you

may have the benefit of our technical facilities.

GUARANTEE REGISTRATION NUMBER IJ002.

WARNING: Do not apply products with metal faceplates directly

to freshly plastered or damp surfaces as product may tarnish. If in

doubt, use polythene as a temporary gasket to protect the

product. Do not use masking tape on metal faceplates.